Features: |
- Voltage range is the MAXIMUM: Nominal voltage of input is between 15%~30%.
- Voltage range is the precisest: After use AVR, the error of voltage output is less than 1%~2%.
- Overload capacity is the strogest: Can resist 150% above sudden overload without causing voltage to go down extremely.
- Reaction time is the fastest: The speed ofvoltage regulation is lower than 0.1 second .
- Output efficiency is the best:From zero to full loading, the output efficiency is all above 95%.
- Modeling-Design,easy to maintain.
- Main AVR use H-grade material:Can prolong the life of machine.
- LED display restoration mode.
- Safety hiding-style switch shield:Can prevent damage from carry, and avoid mistake in operation.
|
Funtions: |
While input voltage exceed voltage limit, AVR will cut off the output to avoid non-normal voltage go into Machine to occur any damage.
- Too low voltage protecting fuctions:If input voltage is too low to cause malfuctions of automatic operation and increase numbers of bad processing products.
- R.S.T non-phase protection: when machine is in motion, if one of the electric cords are disconnected suddenly, THE AVR will immediately stop electricity supply and flush the RED light. To make sure MACHINE in safety condition and to avoild serious damage.
- Sudden Electricity-Breaking Prolonging Protectuon: When electricity is outage for a very short time, It is the easiest to cause to serious magage to machines and equipments. This function can prevent this sutuation happen.
- Overload protecting function: When machine eletrcicity usage is over AVR normal voltage, The AVR will turn off the power to protect machine.
- Short circuit protecting function: When AVR outpit has a short circuit, the AVR will automatucally switch off power to protect machine.
- Second switch fuction: The switch is for maintainance issue only. Not affect to machine operation.
- Adjustable output voltage function: AVR output voltage can be adjusted ± 10% of input voltage according user requirement. So it can be used for various machines.
- Switching on AVR self-detecting fuction: To keep outupt voltage correct, this fuction will avoild any output immediately while the AVR just swith on.
- AVR designed to constant voltage individually: Automatic machine is easy to ahve abnormal operantion while input is three-phase with unbalance. But after our AVR, the output will be balance.
- Power source abnormal indicator: The AVR will indicate abnormal condtion and reasons through abnormal indicators.
|
| ......................................................................................................................................................................................................................... |
Product specification: |
Specifiaciton of Single phase:
 |
| Model No. |
PS-103
AS/BS/CS |
PS-105
AS/BS/CS |
PS-107
AS/BS/CS |
PS-110
AS/BS/CS |
PS-115
AS/BS/CS |
PS-120
AS/BS/CS |
PS-130
AS/BS/CS |
PS-140
AS/BS/CS |
| Capacity |
3KVA |
5KVA |
7.5KVA |
10KVA |
15KVA |
20KVA |
30KVA |
40KVA |
| Voltage |
AS : 1P2W 100V or 110V or 115V or 120V (Input and Output are the same)
BS : 1P2W 200V or 220V or 230V or 240V (Input and Output are the same)
CS : 1P2W or 1P3W 110V system or 220V system (Input and Output are different)
* All CS Type are with Isolated Transformer added. * |
| Input Range |
±15% 50 / 60Hz±5% |
| Regulation |
1% |
| Efficiency |
98% |
| Response Time |
0.1 second |
Pro-
tection |
Over Voltage |
Option |
| Overload |
Standard Feature |
| By-Pass |
Standard Feature |
Standard Feature |
Indi-
cators |
Volt. Meter |
Standard Feature |
| Current Meter |
- |
Standard Feature |
| Overload |
150% 10 second |
Environment
|
Temperature: 0oC ~ 45oC Humidity: 0 ~ 95% RH |
| W x H x D (cm) |
AS |
21 x 26 x 42 |
27 x 46 x 49 |
41 x 58 x 51 |
50 x 70 x 60 |
| BS |
20 x 17 x 24 |
21 x 29 x 42 |
27 x 46 x 49 |
50 x 70 x 60 |
| CS |
20 x 38 x 24 |
21 x 61 x 42 |
41 x 58 x 51 |
50 x 70 x 60 |
50 x 91 x 60 |
| Weight (KG) |
AS |
22 |
24 |
26 |
37 |
56 |
78 |
91 |
103 |
| BS |
9 |
23 |
25 |
28 |
54 |
66 |
81 |
100 |
| CS |
37 |
57 |
76 |
82 |
155 |
180 |
245 |
300 |
|
| * All specification are subject to change without notice. |
| ......................................................................................................................................................................................................................... |
Specification of three phase:
|
| Model No. |
PS-310
X/Y |
PS-315
X/Y |
PS-320
X/Y |
PS-330
X/Y |
PS-345
X/Y |
PS-360
X/Y |
PS-
375
X/Y |
PS-3100
X/Y |
PS-3120
X/Y |
PS-3150
X/Y |
PS-3180
X/Y |
PS-3200
X/Y |
| Capacity |
10KVA
|
15KVA |
20KVA
|
30KVA |
45KVA
|
60KVA |
75KVA
|
100KVA |
120KVA |
150KVA |
180KVA |
200KVA |
| Voltage |
X1 : 3P3W 190V system or 3P4W 110 / 190V system (Input and Output are the same)
X2 : 3P3W 220V system or 3P4W 127 / 220V system (Input and Output are the same)
X3 : 3P3W 380V system or 3P4W 220 / 380V system (Input and Output are the same)
X4 : 3P3W 415V system or 3P4W 240 / 415V system (Input and Output are the same)
Y1 : Input 3P3W 220V or 380V or 415V
Output 3P4W 110 / 190V system (Input and Output are different)
Y2 : Input 3P3W 220V or 380V or 415V
Output 3P3W 220V system or 3P4W 127 / 220V system (Input and Output are different)
Y3 : Input 3P3W 220V or 380V or 415V
Output 3P3W 380V system or 3P4W 220 / 380V system (Input and Output are different)
Y4 : Input 3P3W 220V or 380V or 415V
Output 3P3W 415V system or 3P4W 240 / 415V system (Input and Output are different)
*All Y type are with lsolated Transformer added.* |
| I / P Range |
±15% 50 / 60HZ ±5% |
| Regulation |
1% |
| Power Factor |
0.95~1 |
| Efficiency |
98% |
| Response Time |
0.1 second |
Pro-
tection |
High Voltage |
Standard Feature |
| Low Voltage |
Standard Feature |
| Phase-Failure |
Standard Feature |
| By-Pass |
Standard Feature |
Indi-
cators |
Power |
Standard Feature |
| Voltage |
Standard Feature |
| Abnormal |
Standard Feature |
| Overload |
150% 10 second |
| Environment |
Temperature: 0oC~45oC Humidity: 0~95% RH |
Dimension
WxHxD
(cm) |
X1, X2 |
30x55x59 |
38x67x78 |
49x80x99 |
50x90x100 |
50x130x100 |
| X3, X4 |
30x55x59 |
38x67x78 |
49x80x99 |
50x90x100 |
50x130x100 |
| Y1, Y2 |
30x92x59 |
38x67x78 |
(49x80x99)x2 |
(50x90x100)x2 |
(50x130x100)+
(50x105x100) |
| Y3, Y4 |
30x92x59 |
38x67x78 |
(49x80x99)x2 |
(50x90x100)x2
|
(50x130x100)+
(50x105x100) |
| Weight (KG) |
X Type
|
66 |
73 |
77 |
89 |
155 |
190 |
250 |
300 |
360
|
430 |
455 |
500 |
| Y Type |
140 |
170 |
207 |
220 |
358 |
475 |
250+320 |
300+500 |
360+610 |
430+660 |
455+800 |
500+880 |
|
| * All specification are subject to change without notice. |
|
|